Make the right choice for a better milk production of your dairy farm. The modular GEA milking control technology evaluates your data for precision livestock farming to control your processes.
Metatron Premium 21 and Select 21

Buku panduan gea medical controller


The seamless integration of Metatron 21 and DairyPlan C21 opens up completely new possibilities for optimizing your work flow directly in the milking stall. Metatron 21 records all of the data that is generated, such as milk yield, conductivity or input (e.g. selection marker) and sends the data to DairyPlan C21 for further processing. The latest values are then compared with the values saved in DairyPlan C21. Thanks to the graphical presentation of this information, it can be easily viewed at any time with just a quick glance directly at the Metatron P21 Terminal.

Metatron Select ensures automatic control of the pulsation system – the milk flow controlled follow-up milking and automatic removal as well as the optional time-controlled removal process. Furthermore, Metatron Select can be combined with Metatron Premium: Metatron P21 can be fitted to your integrated gate controller, e.g. on the first and last milking stalls, and Metatron S21 can be fitted in the remaining milking stalls.

DemaTron 60, DemaTron 70, DemaTron 75

Buku panduan gea medical controller

Are you looking for an economical way of introducing milk yield monitoring and cluster removal? Then you will find out, that the DemaTron 60 and the DemaTron 70 control units are absolutely the top products with regard to their price/performance ratio. DemaTron 60 controls and monitors the milking process ranging from pulsation up to automatic cluster removal. The milk yield recorded by the special LactoFlow monitor is used as the basis for controlling an effective milk management process. DemaTron 70 will additionally provide you with precise information of the milk yield, together with the removal of the clusters. The milk flow and milk yield monitoring information – provided by Matatron MB – can be used to optimize the removal function and udder  health as well. The benefits for you are a safe monitoring of the milking process and optimum stripping. For manual animal identification in the parlor we offer DemaTron 75.

Specifications

Model

Milking Control Units Metatron, DeMax & DemaTron

Documents

100% found this document useful (1 vote)

2K views

4 pages

Description:

Daftar Error YP90-100

Copyright

© © All Rights Reserved

Available Formats

DOC, PDF, TXT or read online from Scribd

Share this document

Did you find this document useful?

100% found this document useful (1 vote)

2K views4 pages

GEA YP90-YP100 Error List & Trobleshooting

 

TABLE 3.1 ALARM (CONTINUE)ALARM MESSAGE DESCRIPTIONCode H0.1 ROM inside of main MCU fails. At this time, the heater will stop working ,press Silence/Reset Key to clear alarming for 4min, please refer to theservice part.Code H0.2 Internal system inside of main MCU fails. At this time, the heater will stopworking,  press Silence/Reset Key to clear alarming for 4min, please refer to the service part.Code H0.3 Communication of main and auxiliary MCU A fails, At this time, the heater will stop working, press Silence/Reset Key to clear alarming for 4min,please refer to the service  part.Code H0.4 ROM inside of auxiliary MCU fails, At this time, the heater will stopworking, press Silence/Reset Key to clear alarming for 4min, pleaserefer to the service part.Code H0.5 Internal system inside of auxiliary MCU fails, At this time, the heater willstop working, press Silence/Reset Key to clear alarming for 4min, pleaserefer to the service part.Code H0.6 E2ROM inside main MCU fails, At this time, the heater will stop working ,press Silence/Reset Key to clear alarming for 4min, please refer to theservice part.Code H0.7 SRAM failure (including system cord failure). At this time, the heater willstop working, press Silence/Reset Key to clear alarming for 4min, pleaserefer to the service part.Code H0.8 Main ADC failure(e.g., auxiliary system TLV2548, including wrong sample,chip damage, no response and so on). At this time, the heater will stopworking, press Silence/Reset Key to clear alarming for 4min, pleaserefer to the service part.Code H0.9 Auxiliary ADC failure(e.g., auxiliary system TLV2544, including wrongsample, chip damage, no response and so on). At this time, the heater will stop working, press Silence/Reset Key to clear alarming for 4min,please refer to the service  part.Code H1.0 Heat circuit failure(e.g., heater, solid relay, mechanical relay and allcontrol circuit fails). At this time, the heater will stop working, pressSilence/Reset Key to clear alarming for 4min, please refer to the servicepart.Code H1.1 The timer RTC inside the system fails or is not accurate, At this time, theheater will stop working, press Silence/Reset Key to clear alarming for 4min, please refer to the service  part.Code H1.2 If the keyboard circuit is broken, At this time, the heater will stop working,press Silence/Reset Key to clear alarming for 4min, please refer to theservice part.The system indicator is onCode H1.3 If the battery inside of the controller is error, At this time, the heater willstop working, press Silence/Reset Key to clear alarming for 4min, pleaserefer to the service part.PROCEDURE

 

At first, connected power supply, press and hold Set key for 2s as soon as switch on untilAirtemprature indicator displays “ --.-“, and no display on Skin and Set temprature indicator. And then,press Up or Down until Air temprature indicator displays “78.6”, after then, pressSet key to enter intothe system set screen, or press Silence/Reset key to exit.After entering into the set screen, Set temprature indicator displays set code, Air temprature indicator displays the specific set data.Turn on the power switch5-3 I2Press and hold the for 3sEnter passwordPress key, EXIT Press or key to enter password 78.6,Then press key to confirm Error Password checkYES System setting screenPress key or Key, set temperature indicator displaysthe set codePress or Key can change current set value ENDPress key Press and together SAVE and EXIT Return to original set Brightness set of indicator  SERVICE MANUAL FOR INFANT INCUBATOR EDITION/REVISION B/0 CODE 00.1LED Lightness setIndicate the lightness , and set range is 00.1~01.5. The larger the lighter.CODE 00.2 Air temperature sensor compensation Set value of temperature compensation for air temperature sensor , and set range is -5.0~05.0 ,the first figure of set value means the increasing and decreasing value. For Example, 00.2Means that the air temperature adds 0.2 as compensation. -1.3 means that the air temperature reduces as compensation. CODE 00.3 Air flow temperature sensor compensationtemperature compensation for air flow temperature sensor , and set range is -5.0~05.0 , thefirst figure of set value means the increasing and decreasing value. For Example, 00.2means thatthe air flow temperature adds 0.2 ascompensation. -1.3means that the air flow temperaturereduces 1.3 ascompensation.CODE 00.4 Skin temperature sensor compensationSet value of temperature compensation for skin temperature sensor , and set range is-5.0~05.0 , the first figure of set value means the increasing and decreasing value. For Example,00.2means that the skin temperature adds 0.2 as compensation. -1.3means that the skintemperature reduces 1.3 ascompensation.CODE 00.5 Machine Number Set method of machine number, and set range is 00.0~02.0. For example, 00.1 measn No. 1machine, 01.5 means No. 15.CODE 00.6 Motor speed alarm valueSet method of fan speed, and set range is 00.0~25.5. Every 0.1 means 20 rpm. For example,05.0 means 1000 rpm. Alarm will be active if the fan speed is lower than this value.CODE 00.7 Set value of Low deviation for air temperatureSet method of low deviation alarm in air mode, and set range is 00.0~05.0. For example, 00.8means 0.8 . CODE 00.8 Set value of High deviation for air temperatureSet method of high deviation alarm in air mode, and set range is 00.0~05.0. For example, 00.8means 0.8 .CODE 00.9 Set value of low deviation for skin temperature

 

Set method of low deviation alarm in skin mode, and set range is 00.0~05.0. For example, 00.8means 0.8 . CODE 01.0 Set value of high deviation for skin temperatureSet method of high deviation alarm in skin mode, and set range is 00.0~05.0. For example, 00.8means 0.8 .CODE 01.1 Minimum set value of air temperatureSet method of Minimum set value of air temperature, and set range is 20.0~34.0. For example,25.0 means Minimum set value 25.0 . CODE 01. 2 Maximum set value of air temperatureSet method of Maximum set value of air temperature in mode of>37.0, and set range is37.0~39.0. For example, 39.0 means Maximum set value 39.0 . CODE 01.3 Minimum set value of skin temperatureSet method of Minimum set value of skin temperature, and set range is 30.0~34.0. For example,34.0 means Minimum set value 25.0 . CODE 01.4 Maximum set value of skin temperatureSet method of Maximum set value of skin temperature in mode of>37.0, and set range is37.0~39.0. For example, 39.0 means Maximum set value 39.0 . CODE 01.5 Set value of Over temperature alarm A 37 Set method of Over temperature alarm in air mode (set temperatuer 37, and set range is37.5~39.0. For example, 38.0 means over-temp alarm value 38.0 . CODE 01.6 Set value of Over temperature alarm B ( 37 )Set method of Over temperature alarm in air mode (set temperatuer 37, and set range is38.5~40.0. For example, 40.0 means over-temp alarm value 40.0 . CODE 01.7 Set value of air flow Over temperature alarm A (37Set method of alarm value for air flow blocked (set temperatuer 37, and set range is38.5~48.0. For example, 45.0 means alarm value for air flow blocked 45.0 CODE 01.8Set value of air flow Over temperature alarm B (37)Set method of alarm value for air flow  blocked (set temperatuer >37, and set range is 40.5~52.0.For example, 45.0 means alarm value for air flow blocked 45.0 5.4.2 TEST EQUIPMENT REQUIREDThe test equipment listed below is required for troubleshooting the Controller. Equivalent testequipment may be substituted.Digital VOM, FLUKE 8060A31.0Air Flow Temperature SimulationResistor R=23166 Ω / 0.25W/0.5%TABLE 5.1 ERROR CODES